Name
030.Fan_type*
031.EC_Fan_Level1 *
032.EC_Fan_Level2 *
033.EC_Fan_Level3 *
034.Legionel_Auto_function_days
104.RTCSek
105.RTCMin
106.RTCHour
107.RTCDay
108.RTCDate
109.RTCMonth
110.RTCYear
115 ModbusAdresse 1-247
116 ModbusBaudrate 1=19200 2=9600
117 Modbus Paritet 0=None 1=ODD 2=EVEN
118 ModbusAllowWrite 1=Allow write
Datapoint ES1076
Name
DI1_Pressostat
DI2_Solcelle
T1
T2
Relay1_Kompressor
Relay2_Elpatron
Relay3_Kedel
Relay4_Magnetventil
Relay6_Kondensator
Relay7_Ventilator
DA0_0-10 Volt
(only for installers) (1000 = 10V / 500 = 5V) (for EC fan)
Status
(Data bit translation requires external devices to have this feature option.)
Rest_days
Unit_Alarm
(Data bit translation requires external devices to have this feature option.)
T3
FW_Version
(Data bit translation requires external devices to have this feature option.)
Modbus protocol
Mode
RTU RS485 *
Baud
Modbus baud rate (Setpoint)
Start bits
1
Data bits
8
Stop bits
1 stop bit at Even or Odd, 2 stop bit at None
Parity
Modbus parity (Setpoint)
Address
Modbus address (Setpoint)
Registers Map
Support function
3,4,6,17
53
Read Holding Register (4x)
Unit
Modbus Address
(VrntTyp)
(EC LS1)
%
(EC LS2)
%
(EC LS3)
%
103
104
105
106
107
108
109
114
115
116
117
(Evaporator temperature)
(Tank temperature)
Min
Max
29
0
1
30
0
100
31
0
100
32
0
100
33
3
14
1
247
1
2
0
2
0
1
Unit
Modbus Address
OnOff
OnOff
(PV)
°C
°C
OnOff
OnOff
OnOff
OnOff
OnOff
OnOff
Volt
Binär
Day
Binär
°C
Binär
Decimal
Offset Remarks
0
0
0 = AC
1 = EC
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Read Input Register (3x)
Number of Decimal
0
1
7
8
9
10
11
12
13
14
15
16
17
18
19
119
Andere Modbus parameters kunnen
zichtbaar zijn in een Modbus systeem.
Deze parameters mogen niet worden
gewijzigd en kunnen leiden tot uitsluiting van
garantie.
* Een weerstand van 120 ohm wordt geplaatst
tussen A en B op het eerste apparaat en het
laatste apparaat in een RS485-netwerk.
De totale impedantie is 60 ohm.
Offset
0
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0