Download Print deze pagina

DAB E.Sybox Gebruiks- En Onderhoudsaanwijzing pagina 84

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 226
GB
ENGLISH
Figure 14: Diagram of possible menu accesses
6.3 - Structure of the menu pages
When switched on, some presentation pages are displayed showing the
name of the product and the logo, after which the main menu appears.
The name of each menu, whichever it may be, is always at the top of the
display.
The following always appear on the main page:
Status: operating status (e.g. standby, go, Fault, input functions)
Revs per minute: value in [rpm]
Pressure: value in [bar] or [psi] depending on the set unit of measure.
Power: value in [kW] of the power absorbed by the device.
81
If the case occurs the following may appear:
Fault indications
Warning indications
Indications of the functions associated with the inputs
Specific icons
The error conditions are indicated in Table 2, page 76. The other displays
are indicated in Table 9.
Error or status conditions shown on the main page
Identifying code
GO
Motor running
SB
Motor stopped
DIS
Motor status manually disabled
F1
Float function status / alarm
F3
System disable function status / alarm
F4
Low pressure signal function status / alarm
P1
Operating status with auxiliary setpoint 1
P2
Operating status with auxiliary setpoint 2
P3
Operating status with auxiliary setpoint 3
P4
Operating status with auxiliary setpoint 4
Com. icon with
Operating status in multi-pump communication with the address
number
indicated
Com. icon with E Error status of communication in the multi-pump system
EE
Writing and reading the factory settings on EEprom
WARN.
Low voltage
Warning due to lack of supply voltage
Table 9: Status and error messages on the main page
Description

Advertenties

loading

Deze handleiding is ook geschikt voor: