Use a crimping tool (fig. 1 10, page 3) to connect the cables.
Screw the cable when connecting cable 31 (earth).
– Screw on the cable using a cable terminal and serrated washer to one of the vehicle's earth
bolts or
– screw the cable to the bodywork using a cable terminal and a self-tapping screw.
Make sure there is a good earth connection.
If you disconnect the negative terminal of the battery, all data stored in the volatile memories will
be lost.
The following data must be reset, depending on the vehicle equipment options:
– Radio code
– Vehicle clock
– Timer
– On-board computer
– Seat position
You can find instructions for making these settings in the operating manual.
Observe the following installation instructions:
Secure the parts of the camera which are installed in the vehicle in such a way that they cannot
become loose under any circumstances (sudden braking, accidents) and cause injuries to the
occupants of the vehicle.
Secure any parts of the system concealed by the bodywork in such a manner that they cannot
be come loose or damage other parts or cables, or impair vehicle functions (steering, pedals,
etc.).
To prevent damage when drilling, make sure there is sufficient space on the other side for the
drill head to come out (fig. 2, page 4).
Deburr all drill holes and treat them with a rust-protection agent.
Always follow the safety instructions of the vehicle manufacturer.
Some work (e.g. on retention systems such as the AIRBAG etc.) may only be performed by
qualified specialists.
Observe the following instructions when working with electrical parts:
When testing the voltage in electrical cables, only use a diode test lamp (fig. 1 8, page 3) or
a voltmeter (fig. 1 9, page 3).
Test lamps with a bulb (fig. 1 12, page 3) consume voltages which are too high and can
damage the vehicle's electronic system.
When making electrical connections, (fig. 3, page 4), ensure that:
– they are not kinked or twisted
– they do not rub on edges
– they are not laid in sharp-edged ducts without protection.
Insulate all connections.