Too high energy consumption:
Ambient temperature too high (above +43 °C).
The door is opened too often and/or open for too long.
The door is left open.
Damaged door gasket.
Room temperature setting too low.
Counter too packed with foods - air inlet/outlet blocked.
Condenser mesh filter is clogged.
Warm or hot foods are brought into the cabinet too often.
Counter placed in direct sunlight or close to heat-emitting surfaces.
The default settings have been changed.
User menu
This chapter includes setting of alarm values.
The alarm system is divided into 2 systems. The one system only triggers local alarms,
which means that the error codes are only shown at the display.
The other alarm system triggers both alarms at the display, but it also activates the remote
alarm outlet. Each alarm system operates independently of each other.
If a change of the setting is required, get access to the menu by pushing
than 3 seconds. The values are changed by pushing the
P
saved by pushing
Menu access P + 1
Local alarm setting
External alarm setting
Temperature offset
(sensor calibration)
Escorting alarm limits
No. of defrosts
765041480
. To exit the menu, push
LAL
LhL
Lhd
BU
EAL
EHL
ELL
EHd
ELd
CAL CA
ALL
FAS/ESC
dEF
4
Rev. 000
-
+
or
.
°C
Setting the upper alarm limit. At alarm,
the display shows: A2
min.
Time delay for the upper alarm limit.
On/off
Activation of buzzer. The buzzer
sounds at alarms A1, A2. (1=on / 0=off)
°C
Setting the upper alarm limit. At alarm,
the display shows: A3
°C
Setting the lower alarm limit. At alarm,
the display shows: A4
min.
Time delay for the upper alarm limit.
min.
Time delay for lower alarm.
K
-5...+5 K
Activation of escorting alarm limits.
FAS = fixed limits / ESC = limits
following the setpoint
Number of defrosts in 24 hours.
P + 1
for more
keys. The new setting is