Download Print deze pagina

Gram Gastro 07 Gebruiksaanwijzing pagina 33

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 84
Temperature setting
Temperature control :
Temperature regulation :
Error codes on the display
Display code
Description
A2
Local upper alarm LHL is or has been avtivated
A4
External upper alarm EHL is or has been activated
F1
Room sensor error. In the meantime the counter itself will maintain the
set temperature by the memory of the controller. Temperature stability
will be affected.
Service assistance is required.
F2
Evaporator sensor error. Service assistance is required.
The counter will keep running until the error has been mended.
F3*
Condenser sensor error. The counter will keep running, until the error
has been mended. Service assistance is required.
F7*
Indicates that the condenser temperature is too high. The cause might
be a clogged condenser, or too high ambient temperature.
If the condenser or air filter needs cleaning, the counter must be
disconnected at the mains power. Cleaning of the condenser is done
with a brush or a vacuum cleaner.
The air filter can be removed and cleaned in a dishwasher at max.
50  C.
If the ambient temperature is too high, the placement of the counter
might be wrong, and an alternative place should be found. Ventilation
might help.
If this does not help, request service assistance.
* Applies only to counters with built-in compressor.
Acknowledgement of an alarm:
Acknowledge an alarm: push
765041480
P
Press
to see the cabinet temperature setting; the display will
show the set temperature.
P
Keep
pressed. At the same time, press
-
+
Each time
or
degree. When the display shows the desired temperature, let go of
the two keys and the setting has been made.
P
.
Rev. 000
is pressed the temperature will change one
-
+
or
.
37

Advertenties

loading

Deze handleiding is ook geschikt voor:

Gastro 08