• Thermal or amperometric protector (depending on model).
This safety device stops the high pressure cleaner in the event of overheating and/or electrical over-
current.
If it trips, follow the instructions below:
- turn the main switch (1) to "0" and take the plug out of the mains socket;
- press the cleaner gun lever (22) to discharge any remaining pressure;
- wait 10 to 15 minutes for the high pressure cleaner to cool down;
- check that the requirements for the mains power connections have been followed correctly (see the
INSTRUCTIONS MANUAL – SAFETY INSTRUCTIONS), paying particular attention to the extension lead
used;
- reconnect the plug and repeat the start-up procedure described in "OPERATION".
• Safety valve.
This duly calibrated maximum pressure valve discharges any excess pressure should an anomaly develop
in the pressure adjustment system.
• Boiler safety device.
This stops the burner working should the hydraulic circuit overheat as a result of an anomaly in the
temperature adjustment system.
• Burner Control (optional).
This stops the burner working should the combustion flame go out.
• Pressure control/ adjustment valve
This valve, calibrated by the Manufacturer, permits to adjust the operating pressure (job pertaining to the
Specialized Technician) and the pumped fluid to return to the pump's suction unit, avoiding dangerous
pressure levels, when the gun is closed or when a pressure value is set over the maximum level allowed.
• Dry-running control.
This prevents the possibility of the burner running without water.
• Gun Lever Blocking Device.
This safety device (23) allows to lock the lever (22) on the cleaner gun (24) or (40) in the closed position,
preventing accidental activation (Fig. 5, position S).
Check the following parts are included in the packaging of the purchased product:
• high pressure cleaner (models Classic only);
• high pressure cleaner equipped with hose reel and high pressure delivery hose (models Extra only);
• high pressure delivery hose with the quick fit connector (models Classic only);
• cleaner gun (JUPITER only);
• cleaner gun with pressure regulator (JUPITER PRO only);
• lance pipe
• suction unit connections kit;
• hose for detergent suction from an external tank;
• Instructions manual - safety notifications;
• instructions manual - operation and maintenance
• the declaration of conformity
• the warranty certificate;
• booklet with details of service centers;
• nozzle cleaning pin
If you encounter any difficulties, please get in touch with your dealer or an authorized customer service
centre.
20
SAFETY DEVICES
STANDARD EQUIPMENT