3. How to use
Display (fig. A1)
Pos.
Function
1
Five coloured LEDs
2
Temperature selection key
Temperature setting
The temperature selection key
allows you to quickly select one of five preset temperatures,
that are typical for hot water applications: "Hand wash" 35 °C, "Shower" 38 °C, "Bath tub" 42 °C,
"Kitchen" 48 °C and "Cleaning" 55 °C.
Every key press sets the temperature to the next level:
35 °C
38 °C
42 °C
48 °C
55 °C
Pressing the key
once again, starts the cycle all over.
The currently selected temperature is indicated by one of five coloured LEDs.
For further informations please use the online operation and installa-
tion instruction. Please follow the link below or use the QR code via
smartphone or tablet.
https://www.clage.de/links/gma/DCX-Next-GMA-9120-34381
4. Trouble-shooting and service
Repairs must only be carried out by authorised professionals.
If a fault in your appliance cannot be rectified with the aid of this table, please contact the service
organisation of your importer or the Central Customer Service Department. Please have the
details of the typeplate at hand.
CLAGE GmbH
After-Sales Service
Pirolweg 4
21337 Lüneburg
Germany
Phone:
+49 4131 8901-400
Email:
service@clage.de
Venting after maintenance work
1.
Disconnect the instantaneous water heater from the mains (e.g. via deactivating the
fuses).
2. Unscrew the jet regulator on the outlet fitting and open the cold water tap valve to rinse out
the water pipe and avoid contaminating the appliance or the jet regulator.
3. Open and close the hot water tap until no more air emerges from the pipe and all air has
been eliminated from the water heater.
4. Only then should you re-connect the power supply again (e.g. via activating the fuses) to the
instantaneous water heater and screw the jet regulator back in.
5. The appliance activates the heater after approx. 10 seconds of continuous water flow.
Cleaning and maintenance
•
Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use abrasive or
chlorine-based cleaning agents or solvents.
•
For a good water supply, the outlet fittings (e.g. jet regulators and shower heads) should be
unscrewed and cleaned at regular intervals. Every three years, the electrical and plumbing
components should be inspected by an authorised professional in order to ensure proper
functioning and operational safety at all times.
This instantaneous water heater was manufactured conscientiously and checked several times
before delivery. Should malfunctions nevertheless occur, it is usually only due to a bagatelle. First
attempt to switch the house fuses off and on again in order to reset the electronics. Next, try to
remedy the problem with reference to the following table. In doing so, you will avoid unnecessary
expense of customer service assistance.
DCX Next / DCX 13 Next
Problem
Cause
Master fuse tripped
Water stays cold, temperature LED does
not light up
Safety pressure cut-out tripped
Water stays cold, temperature LED does
Safety thermal cut-out tripped
light up
Water stays cold, all LEDs flash
Internal error
Water heats up, all LEDs flash with
Appliance detected an error
exception of the temperature indication
Outlet fitting dirty or calcified
Flow rate of hot water too weak
Fine filter dirty or calcified
Temperature indication LED flashes
Power limit reached
Selected temperature is not reached
Cold water has been added via the tap
Sensor key does not respond correctly or
Display is wet
only sporadically
8
This instantaneous water heater features an automatic air bubble pro-
tection to prevent it from inadvertently running dry. Nevertheless, the
appliance must be vented before using it for the first time. Each time the
appliance is emptied (e.g. after work on the plumbing system, if there is
a risk of frost or following repair work), the appliance must be re-vented
before it is used again.
Solution
Renew or activate fuse
Contact customer service
Contact customer service
Contact customer service
Contact customer service
Clean shower head, jet regulator or sieves
Let clean fine filter by customer service
Decrease the warm water flow at the tap
Tap hot water only; set temperature, check
outlet temperature
Dry display by wiping it with a soft cloth
CLAGE
EN