Download Inhoudsopgave Inhoud Print deze pagina

BFT DEIMOS BT A 400 Installatievoorschriften pagina 27

Actuator voor schuifhekken met tandheugel
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 40
Transmitter database management.
Receiver community management.
To use these advanced features, refer to the universal handheld programmer's
instructions and to the general receiver programming guide.
15) AUTOSET ADJUSTMENT FIG. I1
Enables Motor Torque to be set automatically.
If the power is suddenly disconnected and then restored the automation performs
the operations at autoset speed till the travel limits are identiied.
WARNING!! The autoset operation must be performed only once you have che-
cked that the leaf is moving accurately (opening/closing) and that the mechanical
stops are positioned correctly.
You must run an autoset cycle whenever the slow-down distance (T3) .
WARNING! While the autoset function is running, the obstacle detection function
is not active. Consequently, the installer must monitor the automated device's
movements and keep people and property out of range of the automated device.
WARNING: the torque values set by the autoset function refer to the motor force
set during the autoset cycle. If motor force is edited, an autoset opening and
closing cycle will need to be performed again.
WARNING: check that the force of impact measured at the points provided for
by standard EN 12445 is lower than the value laid down by standard EN 12453.
Setting sensitivity incorrectly can result in damage to property and injury to
people and animals.
16)REVERSING THE OPENING DIRECTION (Fig.S)
KEYS
KEYS
Description
Add Start Key
S1
associates the desired key with the Start command.
Add Pedestrian Key
S2
associates the desired key with the pedestrian command.
(Pedestrian opening space, see technical speciications)
S2
Conirms the changes made to parameter settings and operating
>5s
Erase List
S1+S2
WARNING! Erases all memorized transmitters from the
>10s
receiver's memory.
Pressed BRIEFLY, it gives the START command.
S3
HELD DOWN (>5 sec.), it activates the AUTOSET function.
LED INDICATORS:
POWER
Steadily lit: - Mains power on - Board powered - Fuse F1 intact
START
Lit: START input activated
OPEN
Lit: OPEN input activated
STOP
Unlit: STOP input activated
PHOT
Unlit: PHOT photocell input activated
FAULT 1 PHOT input safety device test input diagnostics
BAR
Unlit: BAR safety edge input activated
FAULT 2 BAR input safety device test input diagnostics
Unlit: leaf fully closed
SWC
Lit: motor limit switch is disengaged
Unlit: leaf fully open
SWO
Lit: motor limit switch is disengaged
Unlit: no error
ERR
LIT: see error diagnostics table
Unlit: remote programming not active
Radio LED only lashing: Remote programming active, waiting for
hidden key.
RADIO
(GREEN)
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset in progress
Fast lashing 10s: Autoset failed
SET
Flashing in sync with Radio LED: Transmitter deletion in progress
Lit 1s: Start/Stop after key S3 pressed
Lit 10s: Autoset completed correctly
17) ADJUSTMENT PROCEDURE
- Before turning the unit on, check electrical connections.
All manuals and user guides at all-guides.com
INSTALLATION MANUAL
- Set the following parameters: Automatic Closing Time, motor force, slow-down
- Set the logics.
- Run the autoset function.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
by standard EN 12453.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
18) INSTALLATION TEST PROCEDURE
1. Run the AUTOSET cycle (*)
2. Check the impact forces: if they fall within the limits (**) skip to point 9 of the
3. Where necessary, adjust the sensitivity (force) parameter: see parameters table.
4. Check the impact forces again: if they fall within the limits (**) skip to point 9
5. Apply a shock absorber proile
6. Check the impact forces again: if they fall within the limits (**) skip to point 9
7. Apply pressure-sensitive or electro-sensitive protective devices (such as a
8. Check the impact forces again: if they fall within the limits (**) skip to point 9
9. Make sure all devices designed to detect obstacles within the system's operating
(*) Before running the autoset function, make sure you have performed all the
(**) Based on the risk analysis, you may ind it necessary to apply sensitive
WARNING! Incorrect settings can result in damage to property and injury to people
and animals.
LED ERR:
distance.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
not overheated by a considerable number of consecutive operations)
procedure, otherwise
of the procedure, otherwise
of the procedure, otherwise
safety edge) (**)
of the procedure, otherwise
range are working properly
assembly and make-safe operations correctly, as set out in the installation
warnings in the drive's manual.
protective devices anyway
Led SET
Lit
Reverse due to
obstacle - Ampe-
rostop
Unlit:
- Check for obsta-
cles in path
Internal system
supervision control
error.
- Try switching the
board of and back
Lit
on again.
If the problem
persists, contact
the technical
assistance de-
partment.
Photocell test
failed
slow
lashing
- Check photocell
connection and/or
logic settings
Led ERR
slow lashing
fast lashing
Photocell test,
Costa o Costa 8k2
Thermal cutout
failed
- Check photocell
- Allow automated
connection and/or
device to cool
logic settings
Limit switch error
- Check limit
switch connec-
tions
Parameters
or Operating Logic
edited
- If the "Slow-down
distance" is edited,
run a new Autoset
cycle to conirm
the new setting.
- If other parame-
ters and/or opera-
ting logic are edi-
ted, hold down S2
for 5s to conirm.
NOTE: In any case,
the Autoset fun-
ction conirms all
changes made to
the board.
DEIMOS BT A 400 - DEIMOS BT A 600 -
and/
27

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Deimos bt a 600

Inhoudsopgave