ENGLISH
14
Technical Data
Art. No
Service connection
Rated input
Max. suction head
Max. head of delivery
Max. delivered quantity
tank capacity
Max. Water temperature
Degree of protection
Weight
instructions before using the appliance. Familiarise
with the control elements and how to use the
appliance properly. Abide by all the safety measures
stated in the service manual. Act responsibly toward
third parties.
The operator is responsible for accidents or risks to
third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
This appliance can be used by child-
ren aged from 8 years and above
and persons with reduced physical,
sensory or mental capabilities or
lack of experience and knowledge
if they have been given supervision
or instruction concerning use of
the appliance in a safe way and un-
derstand the hazards involved.
Children shall not play with the
appliance.
Cleaning and user maintenance
shall not be made by children wit-
hout supervision.
Garden pump
WT - GP 600 K
03015
230 V~50Hz
600 W
7 m
35 m
2800 l/h
-
35 °C
IPX4
6,7 kg
Read and understand the operating
Domestic water supply unit
WT - GP 1000 I
WT - HW 600 K
03016
03017
230 V~50Hz
230 V~50Hz
1000 W
600 W
8 m
7 m
44 m
35 m
3500 l/h
2800 l/h
-
19 l
35 °C
35 °C
IPX4
IPX4
7,7 kg
11,6 kg
Specified Conditions Of Use
The pump is designed for pumping clean water only
to supply the home with water and to use it at home,
in garden, courtyard and for fields. Respecting techni-
cal data and safety precautions.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
Do not use pump at outside temperatures over 40 °C
or under 0 °C
The pump is not suited for long-run operation
(e.g. as a circulation pump in ponds or streams).
When used in this manner, its service life is curtailed
correspondingly. In these cases, then, use a time
switch to secure sufficient idle periods between
cycles of operation.
Do not leave the pump unattended while in
operation in order to prevent subsequent
damages caused by eventual malfunctions. Make
sure to disconnect the device from the grid if you
do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the
existing water-supply network as a pressure-
boosting device.
Never use the pump as a pool circulation
pump.
WT - HW 1000 II
03018
230 V~50Hz
1000 W
8 m
44 m
3500 l/h
19 l
35 °C
IPX4
13,3 kg