• Connect the 6-pin terminal block to the terminal input (4).
• Connect one end of the terminal power supply leads (not
PWR1
PWR2
included) to PWR1 or PWR2 on the terminal block, and
connect the other end to the power supply.
• The power leads should be wired to the 6-pin power
terminal block matching polarities as marked.
• Check the LED
PWR1 / PWR2
(1) on the front panel to make sure that any powered switches
are receiving power.
c) Place on DIN Rail
• The DIN rail has to comply with EN 55022 (overall width 3.5 cm, overall height 0.75 cm). The
roduct may not be installed on any other mounting rails!
• Place the product on the DIN rail and secure it in place.
d) Network Cable Connection
• Use suitable network cables to connect devices and computers to the switch ports.
• All network ports supports auto uplink, which means that no crosslink cables are necessary
to connect multiple network switches.
• Make sure the cables are not bent or crushed.
• We recommend to mark the network cables with suitable adhesive labels or other devices.
This will allow you in case of a fault to know perfectly which connections need to be checked.
Operation
a) DIP Switches (Alarm Control)
• Switch 1 to 8 (ports 1 to 8). If these DIP switches are ON, Alm
LED
(6) will activate if a network connection is severed.
• Switch 9 (power inputs PWR1 / PWR2). Alm
ON if PWR1 or PWR2 fails.
b) Alarm Relay
• The switch has a single 24 V/DC, 1 A alarm relay output, and can be set to trigger when a
network connection is severed a source of power (PWR1 / PWR2) fails or both.
• Alm LED (6) will blink and the alarm relay will trigger a few seconds later.
PWR1
ALM
PWR2
c) LED Indicators
LED
Colour
Green
PWR1 / PWR 2
Green
Red
Alm
Red
Green
SFP
Green
Green
Green
Link/Act
Green
Green
Amber
Port speed
Amber

Care and Cleaning

• Disconnect the product from the mains before each cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as it
can cause damage to the housing and malfunctioning.
• Clean the product with a dry, fibre-free cloth.
All manuals and user guides at all-guides.com
• To deactivate the alarm, set the related DIP switch to
the OFF position.
• To reactivate the alarm, set the related DIP switch to
the ON position after the alarm conditions have been
removed.
Status
Description
ON
Receiving power
OFF
No power received
ON
Port link down or power failure
OFF
No event
ON
SFP connected
OFF
No SFP connected
Flashing
Network activity
ON
Link active
OFF
Link inactive
Flashing
Network activity
ON
Item No. 1697435: 1000 Mbit/s
Item No. 1697437: 100 Mbit/s
Flashing
Item No. 1697435: 10/100 Mbit/s
Item No. 1697437: 10 Mbit/s
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product in accordance
with applicable regulatory guidelines.
You thus fulfill your statutory obligations and contribute to the protection of the environment.
Technical Data
Specification
Input voltage
Output relay (alarm)
Power consumption
MAC address
Ports
Buffer memory
IEEEE
EMI
EMS
LED
(6) will turn
IEC
Filtering/forwarding
rates
RJ45 transmission
SFP transmission
LED indicators
Ingress protection
rating (housing)
Mounting
Operating
Temperature
Storage
temperature
Dimensions
(H x W x D)
Weight
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights
including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2018 by Conrad Electronic SE.
Item No. 1697435
Item No. 1697437
2x (12 - 24 V/DC) via removable
2x (12 - 24 V/DC) via removable
6-pin terminal block
6-pin terminal block
24 V/DC, 1A
24 V/DC, 1A
max. 8 W
max. 8 W
4 K
4 K
6 x RJ45 (Gigabit)
6 x RJ45 (Fast Ethernet)
2 x SFP (Gigabit)
2 x SFP (Gigabit)
4 Mb
4 Mb
IEEE 802.3 – 10BaseT
IEEE 802.3 10BaseT
IEEE 802.3u - 100BaseTX
IEEE 802.3u 100BaseTX
IEEE 802.3ab - 1000BaseT
IEEE 802.3z 1000 Base SX/LX
IEEE 802.3z 1000 Base SX/LX
IEEE 802.3x - Flow Control
IEEE 802.3x - Flow Control
FCC Class A Part 15, VCCI
FCC Class A Part 15, VCCI
Class A
Class A
EN61000-4-2 (ESD)
N61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-3 (RS)
EN61000-4-8
EN61000-4-8
IEC60068-2-27 (shock),
IEC60068-2-27 (shock),
IEC60068-2-32 (freefall),
IEC60068-2-32 (freefall),
IEC60068-2-6 (vibration)
IEC60068-2-6 (vibration)
11.904 Mpps
3.87 Mpps
10 BaseT Cat. 3, 4, 5 UTP/STP
10 BaseT Cat. 3, 4, 5 UTP/STP
100 BaseTX Cat. 5 UTP/STP
100 BaseTX Cat. 5 UTP/STP
1000 BaseT Cat. 5E UTP/STP
62.5/125 μm Multi Mode Fiber
62.5/125 μm Multi Mode Fiber
optic cable, max. 220 m
optic cable, max. 220 m
50/125 μm Multi Mode Fiber
50/125 μm Multi Mode Fiber
optic cable, max. 550 m
optic cable, max. 550 m
9/125 μm Single Mode Fiber
9/125 μm Single Mode Fiber
optic cable
optic cable
PWR1, PWR2, Alm, 1000M,
PWR1, PWR2, Alm, 10/100M,
Link/Act
Link/Act
IP30
IP30
DIN-rail
DIN-rail
-40 to +70 °C, 5 – 95 % relative
-40 to +70 °C, 5 – 95 % relative
humidity (non-condensing)
humidity (non-condensing)
-40 to +85 °C, 5 – 95 % relative
-40 to +85 °C, 5 – 95 % relative
humidity (non-condensing)
humidity (non-condensing)
55 x 120 x 108 mm
55 x 120 x 108 mm
0.56 kg
0.57 kg