Dometic FreshJet
If the lighting should be switched on without the use of a 230 Vw voltage
supply:
➤ Connect the cable with the positive terminal and the negative terminal of
the vehicle battery.
➤ Feed the 12 Vg cable through the opening into the vehicle interior.
8.5
Installing the roof air conditioner with Chillout ADB
(9102900232, 9102900233)
A
NOTICE! Risk of damage
Observe the structural strength of the roof of the vehicle. The roof
of the vehicle must be able to bear the weight of the roof air con-
ditioner. The roof must not be indented or deformed by the weight
of the unit, even over a longer period of time.
See fig. 0
➤ Lift the roof air conditioner onto the roof of the vehicle.
➤ Position the roof air conditioner over the installation opening.
Observe the direction of travel.
Attaching the roof air conditioner
See fig. a
➤ Position the roof air conditioner into the mounting opening using the
conical noses.
See fig. b
➤ Choose the suitable seal in accordance with the following table:
Roof thickness
30 – 45 mm
45 – 60 mm
➤ Position the seal on the mounting frame.
➤ Fasten the mounting frame (3) on the underside of the roof air conditioner
with the 4 screws supplied.
EN
Seal type
thin (2)
thick (1)
Installation