Important! Heating elements operate at 230V.
Important! For each connection the protective conductor must be connected to the
terminal marked
.
1
230 V single phase connection
with a neutral lead, terminals 1-2-3
are bridged, neutral lead to termi-
nal 4, and the protective conductor
to
2
400/230 V two phase connection
with a neutral lead, terminals 2-3
are bridged, neutral lead to termi-
nal 4, and the protective conductor
to
3
400/230 V three phase connecti-
on with a neutral lead, individual
phases are connected to terminals
1, 2, 3 respectively, neutral lead
to terminal 4, and the protective
conductor to
L1=R, L2=S, L3=T, N=neutral lead connection, PE=protective lead terminal
WIRING DIAGRAM
1/N-
~
2/N-
~
3/N-
~
26
1
2
3
4
5
L1
N
PE
1
2
3
4
5
L1 L2
N
PE
1
2
3
4
5
L1 L2
L3
N
PE
Aanbevolen
type aanslu-
itkabel
HO5VV-F3G4
H O 5 V V -
-F4G2,5
H O 5 V V -
-F5G1,5

Advertenties

loading