EMERGENCY PROCEDURE
Every time when emergency situation occurs you should:
•
switch off the working assemblies of the plate
•
disconnect power supply
•
call in the service
•
as some minor faults can be removed by the user in accordance with the be low specified
instructions, before calling the Customer Service please go thro ugh the Table checking
every point.
PROBLEM
1.The appliance is not wor king
2. The appliance does not re spond to
the entered settings
3.The appliance does not re spond
and emits a short si gnal
4.The appliance does not re spond
and emits a long si gnal
5.The whole appliance swit ches off
6. One heating zone switches off,
and "H" is on the display.
7.Residual temperature in di ca tor is
not lighted although the hot pla tes
are still hot
8. Crack in the ceramic plate
9. If the fault still remains
All manuals and user guides at all-guides.com
CAUSE
- power supply failure
-control panel has not been swit-
ched on
- sensors have been to uched for less
than one se cond
- several sensors have been to uched
at the same time
- children lock has been
activated
-improper operation (im pro per sen sors
have been to uched or pro per sensors
have been touched for too short time
- covered or dirty sensor (sen sors)
- no settings have been en te red
within 10 seconds from swit ching
the plate on
- covered or dirty sensor (sen sors)
- limited time of operation
- covered or dirty sensor (sen sors)
- power supply fa ilu re, the ap plian-
ce has been di scon nec ted from the
mains
Danger! Immediately disconnect the ceramic plate from the
mains (fuse) and call the nearest Customer Service Centre.
Disconnect the ceramic plate from the mains (fuse) and call the nearest
Customer Service Centre.
Important!
You are the person responsible for proper condition and operation of the
appliance in your household. If you call the Service for a fault which re-
sulted from improper operation, you will be charged with the costs of the visit
even during the period of warranty. We shall not be held liable for damages
caused by a failure to observe this Manual.
22
ACTION
-check the in-house electric sys tem
fuse, replace if ne ces sa ry
- switch it on
- touch the sensors for a bit lon ger
- always touch only one sen sor
(except when switching off a hotplate)
- switch off the children lock
- again activate the plate
- uncover or clean the sen sors
- again switch on the control panel
and im me dia te ly enter the settings
- uncover or clean the sen sors
- again switch on the hot pla te
- uncover or clean the sen sors
-the residual temperature in di ca tor
will work again after swit ching the
control panel on and off.