Mount the remote motor unit
For the models 7645, 7655 and 7665 the remote motor
unit of the chimney hood is mounted. A choice can be
made between an internal motor, an external wall motor
or a roof motor. With an external wall motor the minimum
distance between the hood and the external motor must
be 5 meters. The hood is connected to an earthed wall
socket. The hood and the motor unit are electrically con-
nected by means of a 6-pole plug connection. Additional
information can be found in the mounting instructions
of the motor involved.
2 ACCESSORIES
Recirculation
If you choose for recirculation, Novy offers the recirculation
kit, type 7640400. This kit includes a recirculation box
that is mounted behind the upper shaft and a Monoblock
recirculation filter.
Extension cable
When mounting the motor unit remotely, it may be desir-
able to mount a longer cable between the cookerhood
and the motor. The extension cable is connected to the
existing cable. The extension cable has a length of 5m.
Accessories circular exhaust tube
− Circular exhaust tube
length 1000 mm Ø150 mm
− Connection piece Ø150 mm
− Curve 90° Ø150 mm
− Aluminium external grill for Ø150 mm
− Wall conduct kit for ducting Ø150 mm including
built-in heat retention non-return valve
− Non-return valve Ø150 mm
General accessories
− Hose clamp adjustment Ø60-215 mm
− Aluminium tape roll 50 m
− Stainless steel cleaner: maintenance product
for cleaning the stainless steel
InTouch
InTouch offers you the possibility to control the Novy
cooker hood from the Novy InTouch induction cooking
plate. The ceiling hood may, as a default, be combined
with InTouch induction cooking plates.
Visit the website for the different models of induction
cooking plates with InTouch.
Window switch
This hood is equipped with a connection for a con tact
window switch. If the hood is to work simultane ously with
a heating appliance that pulls air from the room, and if
the required supply of fresh air can only be through an
open window, it is possible to connect a window contact
switch (not supplied) to the hood.
This ensures the hood only works if the window is open.
When the window is closed, the fan can not be turned on.
A window contact cable set is available as an accessory
(part number 990.033). Using the cable set, it is possible
to make a connection between the hood controller to the
outside of the hood. A window contact switch can then
be connected (not included).
Further information on Novy products, accessories and
services may be found on the internet: www.novy.com
16
906.415
906.417
906.416
906.178
906.420
906.432
906.291
906.292
906.060