5. COMMISSIONING
5.1 Mount the glass plate onto the tower
Press 2 sec. on key
to move the tower up. Take the tower assembly from the cooking plate by pulling it up and place
the tower on the table top. Take the loose glass plate and place it with a turning movement onto the tower (drawing 9
and 10).
5.2 User modes
The unit is by default set for operation in the recirculation mode. If an exhaust to the outside is used anyway, disable the
indicator for saturated recirculation filter as follows:
CHANGE SETTING FOR EXHAUST DUCT TO THE OUTSIDE:
Only disable the programming when mounting an exhaust duct to the outside.
This setting can only be changed when the tower has been disabled and therefore is in the most downward position.
Simultaneously press the key combination [
SETTING BACK TO RECIRCULATION:
Simultaneously press the key combination [
seconds
5.3 Limitation maximum power induction hob (only for 1801 One Power)
The hob can be equipped with a power limitation. If you reach the maximum power it will be impossible to increase the
power on the different cooking zones and a beep signal will sound. This limitation is set at 7400W (32A) by the factory but
it is possible to change it to 4800W (20A) or 3000W (12A).
Before beginning the procedure:
• Make sure there is no more pot on the hob
• Disconnect the appliance from the grid by removing the fuse or turning the circuit breaker off.
• Reconnect the table to the grid
• Start the procedure within 2 minutes after reconnecting the hob to the grid
• Make sure all cooking zones are off.
Procedure:
1) Press simultaneously on both zone selection keys of the
bottom zones during 3 seconds. A beep will sound and the
current power is displayed.
2) To set the power limitation use the [ + ] and [ - ]. To exit the
procedure without saving your changes, don't touch any
key for 60 seconds.
3) To save the new power limitation, press simultaneously
on both zone selection keys of the bottom zones during
3 seconds. Once the new limitation registered, a beep will
sound.
6. ACCESSOIRIES
The following accessories can be ordered with the unit:
• Wall passage for flat duct. Inox/SS incl. non-return valve:
article 906407
• Outside wall grate round duct Ø 150 mm. Aluminium shutter
grate: article 906178
• Non-return valve round duct Ø 150 mm: article 906269
• Aluminium tape, roll 50 metres: article 906292
OPTIONAL (1801 One Power & 1811 One Pro from v13)
Installation I/O module n° 990034
Open the cover of the electrical connection box.
Plug in the I/O module connection cable into the connector.
(See manual 990034 I/O module)
], [
], [
] for 3 seconds until the LED beside the
], [
], [
]for 3 seconds until the LED beside the
blinks 3 times
lights up for 3
EN 23