INSTALLATION
Important! For each connection the protective conductor must be connected
to the terminal marked
1 For a 230 V single phase connec-
tion with a neutral lead, terminals
L1, L2 are bridged, neutral lead is
connected to terminal N, and the
protective conductor to
2* For a 230/400 V two phase con-
nection with a neutral lead, neutral
lead is connected to terminal N, and
the protective conductor to
L1=R, L2=S, L3=T; N = neutral lead connection;
* For domestic 3-phase 230/400 V electrical system, connect the remaining wire to the
terminal:L3, which is not connected to the hob internal electrical system.
* NN terminals are internally connected, they need not be bridged
WIRING DIAGRAM
Important! Heating elements operate at 230V.
.
1N~
.
2N~
.
L1
N
L2
L1
N
= protective lead terminal
17
Fuse
Type /
protec-
Conductor
tion
cross sec-
tion
HO5VV-FG
min.30 A
3X 4 mm
2
HO5VV-FG
min.16 A
4X2,5mm
2