Glowing coals (Not applicable to Pigalle)
The coals have already been fitted in the factory.
Should they need replacing:
• Remove the 8 nuts.
• Remove the glass.
• Remove the broken coals.
• Evenly distribute the glowing coals on the grille in the
combustion chamber (fig. 3).
• Replace the glass.
• Replace and tighten the 8 nuts.
Mounting the casing
To mount the casing, align the pins on the feet of the
heater with the holes at the bottom of the casing front,
ensuring that the back edge of the casing drops into the
brackets.
Floor plate
Position the floor plate under the heater so that the
openings fit round the steel feet of the interior.
This appliance is fitted with a TTB
The TTB is a flue spillage sensor that reacts to flue gasses
flowing past the baffle in the heater back into the living
room.
In the event of a flue spillage, the thermocouple is
interrupted by the TTB, shutting off the gas supply to the
burners.
This protective device will prevent flue gasses from
flowing into the home for any length of time.
fig. 3
INSTRUCTIONS FOR INSTALLATION
The device will reset itself after a few minutes and the
heater can then be reignited.
Possible causes of the TTB being activated
include:
• There is little or no supply of fresh air into the home
(all draughts have been excluded and ventilation openings
sealed off).
• The outlet into the flue duct is partially or completely
blocked.
• The chimney mouth was not constructed correctly, can
cause "fall winds" in the chimney duct being a possible
result.
Measures to prevent TTB activation
The heater can be reignited once the TTB has cooled
down.
If the safety device is activated again, open a window or
some other means of ventilation.
If this resolves the problem, it means that the home is
hermetically sealed and the heater is unable to discharge
all the combustion fumes through the chimney. Some
means of ventilation must be kept open or constructed. If
the safety device is still activated after that, examine the
other possible causes listed above and resolve accordingly.
The safety device may never be disconnected.
N.B.: If the flue spillage sensor is repeatedly
activated, a qualified gas installer should be
contacted.
The TTB
The TTB safety device has several special components that
should also be incorporated in a replacement TTB. You
are strongly advised not to fit a "standard" thermocouple.
15
Pigalle