Download Print deze pagina

HEIDENHAIN TNC7 Handleiding pagina 2158

Verberg thumbnails Zie ook voor TNC7:

Advertenties

41
Foutnummer
126-0110
126-0111
126-0112
126-0113
2158
Beschrijving
Error message
NC-software niet voor FV-toepassing vrijgegeven
Cause of error
- The control system (hardware) was detected as a system
with functional safety (FS) from HEIDENHAIN. However, the
installed NC software has not been approved for applicati-
ons that use integrated functional safety (FS) from HEIDEN-
HAIN.
- The installed software is a test software or an NC software
that has not been released for the application of integrated
functional safety (FS)
Error correction
- Install an NC software version of your control that has been
approved for applications with integrated functional safety
(FS) from HEIDENHAIN.
- Inform your service agency.
Error message
Te veel uitschakelpoorten gedefinieerd
Cause of error
In the IOC file, more than one output was defined for
switching the machine off after shutdown. This is not
allowed. No more that one output can be defined.
Error correction
- Check the IO configuration and correct it if required
Error message
Uitschakelpoort op verkeerd bussysteem
Cause of error
The output for switching off the machine after the control
shutdown was defined for the wrong bus system. The
permitted bus systems are external PL assemblies with
HSCI interface or internal PL assemblies.
Error correction
- Check the IO configuration and correct it if required
Error message
PLC-uitgang voor uitschakelen meermaals geprogrammeerd
Cause of error
A PLC output for shutting down the control (switch-off port)
is defined both in the IOC file as well as in the configuration
data (machine parameters).
Note that the entry in the configuration data has priority.
Error correction
- Check the IO configuration.
- Check the configuration datum DisplaySettings->CfgShut-
down (Maschinen-Parameternummer 101600)
- Inform your service agency
NC-foutmeldingen | Lijst met NC-foutmeldingen
HEIDENHAIN | TNC7 | TNCguide | 01/2022

Advertenties

loading