8
1
8
1
Connectoren A en B
Pin
Functie
1
Transmit +Ve
2
Transmit –Ve
3
Receive +Ve
4
-
5
-
6
Receive -Ve
7
-
8
-
Module menu 0 – Module set-up
Par.nr.
Omschrijving
1.0.001
Moduulcode
1.0.002
Softwareversie
1.0.003
Hardwareversie
1.0.004
Serienummer, laagste karakters
1.0.005
Serienummer, hoogste karakters
1.0.006
Module status
1.0.007
Reset module
1.0.008
Default module
1.0.009
Active alarm bits
1.0.010
Active IP Address
Ethernet en module error codes
Sub-
Text String
trip
100
Link Loss
101
E/IP Timeout
102
E/IP Read Param
103
E/IP Write Param
104
E/IP Fault
105
Modbus Timeout
106
Cyclic Timeout
107
Cyclic RX Late
108
INIT Switch
109
INIT PTP
110
INIT Cyclic
111
INIT Modbus
112
INIT SMTP
113
INIT Ethernet/IP
114
INIT TCP/IP
115
Ethernet Faillure
116
E/IP PLC IDLE
117
Sync Task ORun
118
INIT Param Chann
119
Link Overload
120
Mcast Over Limit
200
Software Fault
201
BG overrun
202
Firmware invalid
ID300 Handleiding versie 2.2
ID300 Optiemodule
SI-Ethernet
Uit - Geen netwerk
A B
Aan - Netwerk actief
Knipperend - Data
Optiemodule frontaanzicht
Kleur: Beige
Moduulcode: 433
Module menu's
1.2.003
Slot
- Menu
Menu nr. Functie
x.0.
Ethernet setup
x.2.
Ethernet configuration
x.9.
Resources
x.10.
Easy mode cyclic data
x.11.
Synchronisation
(gelijk aan menu 15)
Type
Eenh
RO,U
RO,U
RO,U
RO,U
RO,U
RO,Txt
RW,Bit
RW,Bit
RO,Bin
RO,U
Beschrijving
Network link has been lost
Ethernet/IP RPI timeout
Invalid read parameter
Invalid write parameter
Ethernet/IP Error
Modbus connection time out
Cyclic Rx link timeout
Cyclic Rx data received late
Ethernet switch init. error
Precision Time Protocol error
Cyclic data initialization error
Modbus TCP initialization err.
Email (SMTP) initialization err.
Ethernet/IP initialization error
TCP/IP initialization error
Ethernet controller init. error
Ethernet/IP PLC idle
Synchronous task overrun
Parameter channel init. error
Too many links in same cycle
Too many multicast address.
Software Fault
Background task overrun
Invalid firmware for hardware
Pagina 125 van 146
Raadpleeg de Engelstalige
SI-Ethernet handleiding voor de
-
Parameter
beschrijving van menu 2 t/m 23.
Menu nr. Functie
x.15.
x.20.
x.21.
x.22.
x.23.
Fabr.
Bereik
progr.
999
0 = Geen module aanwezig
433 = SI-Ethernet
99.99.99.99
99.99
99 99 99 99
Voorbeeld: 12345678.
x.0.005 = 1234, x.0.004 = 5678
99 99 99 99
Bootldr-
The bootloader is performing a
Update
(-2)
flash update
Bootldr-Idle(-1) The bootloader is Idle
Initializing (0)
Module is initializing
OK
(1) Initialized and no errors
Config
(2) Configuration error
Error
(3)
Error
Off (0)
On (1)
Off (0)
On (1)
- Programmeer x.0.008 op On
- Programmeer x.0.007 op On
65535 (16bit)
0 = User Program, 1 = eCMP
2 = Modbus,
4 = Reserved,
6 = Too Hot
Maximum 127.255.255.255
Sub-
Text String
trip
203
Drive unknown
204
Drive unsupported
205
Mode unknown
206
Mode unsupported
207
FLASH Error
208
Database init
209
File System init
210
Mem Allocation
211
Filesystem error
212
Config Save
213
Over Temperature
214
Drive Timeout
215
eCMP comms error eCMP comms failure
216
TO eCMP slot 1
217
TO eCMP slot 2
218
TO eCMP slot 3
219
TO eCMP slot 4
220
I/O Overload
221
Factory Settings
222
Functional Test
223
Config Restore
224
Self Test Error
225
Runtime Config
226
Processor exept
227
Task Starvation
Modbus
Ethernet IP setup
Ethernet IP in mapping
Ethernet IP out mapping
Ethernet IP fault values
Bijzonderheden
3 = Ethernet IP
5 = File system
Beschrijving
Unknown drive type
Unsupported drive type
Unknown mode
Unsupported drive mode
Corrupted non-volatile flash
Database initialization error
File system initialization error
Memory allocation error
File system error
Configuration file save error
Overheated
Drive not responded (W-dog)
Slot 1 eCMP comms timeout
Slot 2 eCMP comms timeout
Slot 3 eCMP comms timeout
Slot 4 eCMP comms timeout
Digital output current too high
Missing factory settings
Functional test faillure
Configuration file restore error
Power on self test error
Runtime configuration error
Processor exception
System task starvation