Operation
14

Error messages

There are a few error situations in which the limiter will switch off its output, while one of the
LED's at the front will blink to indicate that there is something wrong.
DETECT-LED (8) blinking: limiter is initialising after switching the power on.
This situation will not last langer than a 2 seconds.
DETECT- & WARNING-LED (8) (11) blinking: limiter is initialising after
switching the power on. In this case, the measuring microphone is switched
on.
WARNING- & SANCTION-LED (11)(12) blinking: the supplied microphone is
not connected correctly. Check the connection.
BYPASS-LED (7) blinking: the limiter is in BYPASS-mode, and will simply
pass all audio on the input directly to the output.