Drive controller
If. the. UCR50. is. used. as. a. drive. controller,. the. drive. is. connected. directly. to.
the.device..External.signals.are.converted.into.control.commands..The.coding.
switch..must.be.in.the.lower.position.
Group controller
If.the.UCR50.is.used.as.a.group.controller,.other.group.controllers/drive.con-
trollers.can.be.controlled..This.control.can.relay.external.switching.signals.
This.function.can.be.used.to.connect.groups.and.carry.out.joint.switching.com-
mands..The.coding.switch..must.be.in.the.upper.position.
Roller shutter or venetian blind
Encoding.Switch.3.is.used.to.select.roller.shutter.mode.(lower.position).or.vene-
tian. blind. mode. (upper. position).. When. the. venetian. blind. mode. is. selected,.
the.venetian.blind.moves.in.nonmaintained.command.mode.in.order.to.allow.
for. the. blind. slats. to. be. positioned. precisely.. If. a. control. command. button. is.
held.pressed.for.more.than.1.second,.the.venetian.blind.will.move.in.maintained.
command.mode.
Functions in manual mode (on the device and via radio
control)
•. UP,.STOP,.DOWN
•. Intermediate.position
•. Ventilation/adjustment.position
•. Emergency.signals
Functions in automatic mode
•. External.automatic.drive.commands
•. UP,.STOP,.DOWN
•. Intermediate.position
•. Ventilation/adjustment.position
•. Emergency.signals
Settings
Functions
DE
GB
FR
NL
3