9.7.1.3 Interior lining

9.7.1.3.1 Vermiculite

The fire's vermiculite plates are located on the bottom against the rear wall and/or side walls of the appliance. In
the following situations the vermiculite plates must be taken out:
When disassembling the air slide valve (see section 9.7.1.2).
To be able to reach the adjustable legs (see section 9.6).
When replacing the vermiculite plates.
The bottom plates and the underlying felt are first removed and the rear plates last. The insertion of the
vermiculite plates takes place in reverse order.
Make sure that the vermiculite plates are replaced in the original position! The back plate with the small, not
!Caution
countersunk, holes must be placed to the front.

9.7.1.3.2 Flame baffle plate

On delivery the flame baffle plate (see appendix 2, fig. 19) is located in the top section of the appliance. The flame
baffle plate must be removed in a number of situations:
when mounting and checking the flue gas exhaust connection;
when performing maintenance at the flue duct;
when replacing the flame baffle plate.
For removing the flame baffle plate, proceed as follows:
Ø
Lift the left side of the flame baffle plate until it gets above the edge and slide the flame baffle plate to the right.
Ø
Lower the left side of the flame baffle plate and slide the flame baffle plate to the left.
Ø
Slide the right-hand side of the flame baffle plate over the edge.
Ø
Slide the flame baffle plate to the left and lower it until it reaches the lower section of the appliance.
Ø
Now you can remove the flame baffle plate.
Placing the flame baffle plate takes place in reverse order.
The stainless steel profile must be placed at the front with the screw heads on top (see appendix 2, fig. 19).
!Caution
EA
9.7.2 Instyle 700

9.7.2.1 Air slide valves

With installation and maintenance of the appliance check the operation of the air slide valves (see Appendix 2,
Fig. 20). There is the possibility that steel grit entered the air slide valves during transport. If the air slide valves
does not move smoothly they must be cleaned. The air slide valves must be disassembled to do this. The air slide
valves are suspended sprung by means of a bolt and a spring located below the cover plate.
Proceed as follows when disassembling the air slide valves (see Appendix 2, Fig. 20):
Ø
Remove the vermiculite plates from the bottom (see section 9.7.2.3.1).
Ø
Remove the cover plate from the bottom.
Ø
Remove the socket screw with spring.
Ø
Remove the air slide valves by bringing them towards you.
Ø
Check the air slide valves and clean them if necessary.
To replace the air slide valves proceed as described for removal in reverse order.
9.7.2.2 Interior lining
9.7.2.2.1 Vermiculite
The fire's vermiculite plates are located on the bottom against the side walls of the appliance. In the following
situations the vermiculite plates must be taken out:
When disassembling the air slide valve (see section 9.7.2.1).
To be able to reach the adjustable legs (see section 9.6).
When replacing the vermiculite plates.
The bottom plates are first removed and the side plates last. The insertion of the vermiculite plates takes place in
reverse order.
Make sure that the vermiculite plates are replaced in the original position!