Download Inhoudsopgave Inhoud Print deze pagina

Amica PG4VI515FTB4P3 Gebruikershandleiding pagina 17

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

INSTALLATION
Important! For each connection the protective conductor must be connected
to the terminal marked
1 For a 230 V single phase connec-
tion with a neutral lead, terminals
L1, L2 are bridged, neutral lead is
connected to terminal N, and the
protective conductor to
2* For a 230/400 V two phase con-
nection with a neutral lead, neutral
lead is connected to terminal N, and
the protective conductor to
L1=R, L2=S, L3=T; N = neutral lead connection;
* For domestic 3-phase 230/400 V electrical system, connect the remaining wire to the
terminal:L3, which is not connected to the hob internal electrical system.
* NN terminals are internally connected, they need not be bridged
WIRING DIAGRAM
Important! Heating elements operate at 230V.
.
1N~
.
2N~
.
L1
N
L2
L1
N
= protective lead terminal
17
Fuse
Type /
protec-
Conductor
tion
cross sec-
tion
HO5VV-FG
min.30 A
3X 4 mm
2
HO5VV-FG
min.16 A
4X2,5mm
2

Advertenties

Hoofdstukken

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Pg4vi515aftb4p3

Inhoudsopgave