16. H
ISTORIE VAN DE HANDLEIDING UPDATES
Described in the table below are changes as compared with the manual for the ACU-100
controller with firmware in version v 1.03.
F
IRMWARE
D
ATE
VERSION
2005-09
1.04
2006-11
1.05
2007-11
1.06
2008-07
2.00
2009-07
2.01
• Added information on the options of programming the outputs of the controller and
ACX-100 module as NO, NC type (p. 8 and 41).
• Added description of the manner to indicate active status of functional outputs
(p. 9).
• Supplemented service mode menu of the LCD keypad connected to the controller
(p. 36).
• Information about new wireless devices added to section on controller outputs
(p. 8).
• Information added regarding new wireless devices of ABAX system: ACX-200
zone/output expander (p. 9 and 20), ASP-205 wireless indoor siren (p. 12),
ASW-100 E and ASW-100 F 230 V AC wireless controllers (p. 13 and 27) and
ARF-100 radio signal level tester (p. 13 and 27).
• Modified section on adding new devices to ABAX system (p. 17–20).
• Supplemented section on interaction between ACU-100 controller and INTEGRA
control panels (p. 28).
• Added information on the diagnostic capability of ACU-100 controller operating in
configuration of expander of wireless devices for INTEGRA series control panels,
by means of D
10 program (p. 33 and 37).
LOAD
• Supplemented information on "Test mode" (p. 42).
• Supplemented description of LBA function output (p. 6, 9).
• Added information on new wireless devices of ABAX system: hard-wired zones
and outputs expander with power supply ACX-201 (p. 10, 20), wireless dual
motion detector (p. 10), wireless glass break detector (p. 11), wireless water flood
detector (p. 11), wireless vibration and magnetic detector (p. 11) and wireless
smoke and heat detector (p. 11).
• Modified section on adding new devices to ABAX system (p. 17–20).
• Added information on lowering the radio signal level during test mode operation
(p. 28, 43).
• Modified and supplemented description of "Battery status" function (p. 42).
• Information on pet immunity has been added to description of APD-100 detector
(p. 10).
• Information on APD-100 detector configuration has been modified and
supplemented (p. 23, 44 and 47).
• Information on AMD-100 and AMD-101 detector configuration has been modified
and supplemented (p. 24, 45 and 47).
• Added information on interaction with VERSA control panel.
• Modified section on controller control inputs (p. 7).
• Modified section on controller control outputs (p. 8).
• Added information about AMD-102 wireless magnetic contact with roller shutter
input (p. 11, 24, 45 and 47).
• Added information about ARD-100 wireless reorientation detector (p. 12, 24, 46
and 48).
• Added information about APT-100 bidirectional keyfob (p. 13).
• Revised section "Installation":
– subsections on detectors (p. 22), sirens (p. 25), wireless controllers (p. 27) and
radio signal level tester (p. 27) have become separate subsections and all of
them have been modified;
– information on installation of particular wireless devices has been deleted (it
can be found in manuals of respective devices);
– description of configuration of particular devices has been moved to section
"Configuration of additional parameters and options in wireless devices"
(p. 44).
• Added information about the method of configuration of INTEGRA system zones
to which wireless devices are assigned (p. 31).
SATEL