Ia
equipment in compliance with specific building rules for intrinsically save
Ib
equipment
equipment in compliance with specific building rules for intrinsically save
equipment
ec
equipment in compliance with specific building rules for non-sparking save
equipment
IIC
equipment for use with gas of subdivision C
IIIC
equipment for use in places with conductive dust.
T4
equipment whose surface temperature does not exceed 135°C with < 70°C
Ambient temperature.
T100°C
maximum surface temperature of the equipment covered with a dust layer of 5
mm
Ingress Protection Grade, Series 2000, 2000-SAN, CER-2000: IP 66
Ingress Protection Grade, Series 2000-Hydrobar-Cable and 2000-Hydrobar-EXTD: IP 66
The Hydrobar-I-Cable and all other submersible parts from the Series 2000-Hydrobar,
2000-Cable and 2000-SAN-Cable are IP 68.
Furthermore, whatever the protection mode, only use cable glands with a protection degree
of at least IP 66. Be sure the cable diameter complies with the selected cable gland. Tighten
the cable gland in a proper way. Never forget to mount the covers of the electronics
housings in a proper way.
For other technical details, refer to the instruction manuals of the transmitters.