Certify that the equipment intended for use in potentially explosive atmospheres, only new products, indicated here after:
Are in accordance with:
-
Directive 2014/34/EU of 26
explosive atmospheres).
-
Directive 2014/30/EU of 26
(Electro Magnetic Compatibility).
-
Harmonized standards:
EN 60079-0: 2012 (General rules)
EN 60079-11: 2012 (Intrinsic safety "i")
EN 60079-26:2007 (Group II cat. 1G requirements)
IEC 61000-6-2: 2001 (EMC, Immunity in industrial location)
IEC 61000-6-3: 2001 (EMC, Emission in industrial location)
IEC 61000-6-4: 2001 (EMC, Emission in industrial location)
EN-ISO-IEC 80079-34: 2011 (Potentially explosive atmospheres – Application of quality systems
The type (protection mode "ia") which has been the subject of;
-
EC-type Examination Certificate Numbers:
KEMA 03 ATEX1219 X
Delivered by the KEMA, Meander 1051, 6825 MJ Arnhem, The Netherlands, notified body Nr. 0344,
Manufacturing plant in Dwingeloo which has been the subject of;
Production Quality Assurance Notification Nr.:
DEKRA 12ATEXQ0041
Delivered by the DEKRA, Meander 1051, 6825 MJ Arnhem, The Netherlands, notified body Nr. 0344
st
Date: April 21
E. Timmer
Managing Director - Klay Instruments B.V.
The marking of the equipment is as follows:
''II''
means that the equipment has been built for use in surface industries (and not in mines endangered
by firedamp).
''1''
equipment for use in Zone 0 (if G)
''G'''
equipment for use with gas, vapours or mists
''Ex''
equipment in compliance with European standards for
explosive atmospheres
''ia''
equipment in compliance with specific building rules for intrinsically save equipment
''C''
equipment for use with gas of subdivision C
''T4''
equipment whose surface temperature does not exceed 135ºC when used in an ambient temperature
< 70 ºC.
Protection Grade, Series 8000-SAN, 8000, CER-8000, IP 66
Protection Grade, Series Hydrobar-cable, Hydrobar-EXTD, IP 66
The Hydrobar-FR and all other submersible parts from the Series Hydrobar are IP 68.
Furthermore, whatever the protection mode, only use cable glands with a protection degree of at least IP 66.
Be sure the cable diameter complies with the selected cable gland. Tighten the cable gland in a proper way.
Never forget to mount the covers of the electronics housings in a proper way.
For other technical details, refer to the instruction manuals of the series transmitters.
Nijverheidsweg 5
P.O. Box 13
EU-DOC/06-2016/10
EU-DECLARATION OF CONFORMITY
Klay Instruments B.V.
Nijverheidsweg 5, 7991 CZ Dwingeloo, The Netherlands
Electronic Pressure- and Level Transmitters
Series 8000-SAN, Series 8000, Series CER-8000
Hydrobar-Cable, Hydrobar-EXTD, Hydrobar-FR
th
February 2014 (equipment and protective systems intended for use in potentially
th
February 2014.
2016
7991 CZ Dwingeloo
7991 AA Dwingeloo
Signature:
II 1G Ex ia IIC T4 Ga
Tel.: +31 521 591550
Fax.: +31 521 592046
The Netherlands
e-mail: info@klay.nl